15 kVA Single-Phase Pad-Mounted Transformer

The 15 kVA Single-Phase Pad-Mounted Transformer from HEAKOR is a liquid-filled unit intended for smaller underground electrical distribution applications serving residential, commercial and utility projects.

Maklumat produk tersenarai

Jenis produk
Dipasang pada pad
Kuasa terkadar tersenarai
15 kVA
Bilangan fasa
Fasa tunggal

Butiran ini mengenal pasti produk tersenarai. Spesifikasi dan lukisan yang diluluskan mentakrifkan peralatan yang dibekalkan.

Sebutharga berdasarkan keperluan projek
Minta sebut harga projekBaca maklumat produkBuka pusat dokumen
Elektrik

kuasa terkadar · voltan · fasa · frekuensi

Projek

Permohonan · destinasi · kuantiti · jadual

Dokumen

Spesifikasi · lukisan · kelulusan yang diperlukan

Spesifikasi, piawaian, skop pensijilan dan terma komersial perlu disahkan untuk peralatan dan projek yang dicadangkan.

Each transformer is configured according to the approved project specification. Primary voltage, secondary voltage, feed arrangement, insulation level, tap requirements, accessories and applicable standards must be confirmed before quotation and production.

15 kVA Single-Phase Pad-Mounted Transformer: Listed Product and Project Requirements

  • Listed Capacity: 15 kVA
  • Phase: Single-phase
  • Product Type: Liquid-filled pad-mounted distribution transformer
  • Installation: Outdoor, pad-mounted

Requirements to provide for engineering review

  • Frequency: State the required site frequency, including 60 Hz where specified by the project.
  • Primary Voltage: Provide the system voltage, phase-to-neutral voltage where applicable, grounding arrangement and utility specification.
  • Secondary Voltage: State the required output voltage and connection arrangement.
  • High-Voltage Interface: State any dead-front or live-front requirement and the required cable interfaces.
  • Tap Requirements: Provide the specified tap range and increments, or mark TBC for review.
  • Feed Arrangement: State the radial-feed or loop-feed requirement.
  • Insulation Level: Provide the required BIL and primary voltage class, or mark TBC for review.
  • Insulating Liquid: State any specified liquid and relevant environmental or fire requirements.
  • Standards and Edition: Provide the project or utility specification. If IEEE C57.12.38-2025 is required, its scope and the proposed equipment must be reviewed together.

These inputs define the requested equipment. Available configurations, conformity, test evidence and supply scope require confirmation for the proposed design. A standard reference alone does not establish product conformity.

Applications

This transformer may be considered for smaller residential properties, small commercial facilities, project auxiliary loads and other underground single-phase distribution applications.

Final suitability depends on the load calculation, system voltage, installation environment and applicable utility requirements.

Request a 15 kVA Single-Phase Pad-Mounted Transformer Quotation

Please provide:

  • Primary voltage
  • Secondary voltage
  • Frequency
  • Required quantity
  • Radial-feed or loop-feed requirement
  • Dead-front or live-front requirement
  • Required BIL
  • Applicable standard
  • Destination country
  • Required accessories and protection devices
  • Installation environment
  • Single-line diagram or technical specification, if available

Can 15 kVA serve a small property?

The site description alone does not determine capacity. Provide the connected loads, expected simultaneous demand, and proposed service voltage so the 15 kVA rating can be reviewed against the actual project.

Engineering Review

The voltage ratio, BIL, tap arrangement, terminal configuration, enclosure, insulating liquid, protection requirements, accessories and applicable standard will be reviewed for each project.

The product image illustrates this transformer family. Final enclosure dimensions and terminal layout must follow the approved project drawing.

Request a technical quotation with your specification, quantity and destination. For other ratings, view the single-phase pad-mounted transformer collection.

Sebelum meminta sebut harga

Sahkan kesesuaian untuk projek anda.

Nama produk atau kuasa terkadar ialah titik permulaan. Sertakan keperluan ini supaya cadangan boleh disemak terhadap projek anda.

01

Keperluan elektrik

Kuasa, voltan primer dan sekunder, bilangan fasa, frekuensi serta keperluan sambungan, impedans atau tap yang dinyatakan.

02

Keperluan pemasangan

Terangkan susunan bekalan elektrik, sambungan kabel, akses kabinet dan susun atur tapak. Sertakan projek atau spesifikasi operator rangkaian elektrik.

03

Dokumen dan skop bekalan

Nyatakan lukisan, ujian atau kelulusan, kuantiti, destinasi dan jadual projek yang diperlukan. Kenal pasti sebarang keperluan wajib sebelum sebut harga.

Bagaimana jika beberapa spesifikasi belum diketahui lagi?

Hantar maklumat yang anda miliki dan tandai item yang tidak diketahui sebagai disahkan. Untuk penggantian, papan nama sedia ada, gambar peralatan dan kekangan tapak membantu menentukan semakan. Nilai elektrik berkadar akhir dan skop bekalan mesti dipersetujui dalam sebut harga dan dokumen yang diluluskan.

Bincangkan produk ini

Dokumen projek

Dokumen yang betul. Untuk model yang betul.

Nyatakan dokumen yang diperlukan oleh projek anda. Ketersediaan dan skop yang terpakai disemak untuk model dan konfigurasi yang dicadangkan.

01 / DOKUMEN

Helaian data dan nilai terkadar

Kenal pasti model yang dicadangkan dan nilai elektrik terkadar yang mesti dilindungi oleh dokumen.

Permintaan untuk projek anda
02 / DOKUMEN

Lukisan dimensi keseluruhan dan sambungan elektrik

Nyatakan keperluan pemasangan, kemasukan kabel dan kelegaan yang perlu anda periksa.

Permintaan untuk projek anda
03 / DOKUMEN

Dokumen ujian dan kelulusan

Namakan ujian, standard atau kelulusan yang diperlukan dan model atau konfigurasi yang berkenaan.

Permintaan untuk projek anda

Minta dokumen untuk konfigurasi cadangan anda

Sertakan model atau jenis produk, kuasa terkadar, voltan, frekuensi dan destinasi. Minta nombor laporan, tarikh dan skop ujian supaya anda boleh menyemak sama ada dokumen sepadan dengan konfigurasi yang dicadangkan. Laporan individu tidak menetapkan pensijilan untuk setiap model atau destinasi.

Apabila menyemak dokumen, padankan entiti undang-undang, model, nilai elektrik terkadar, skop yang berkenaan dan tarikh pengeluaran dengan peralatan yang dicadangkan anda.

Baca panduan skop sijilBuka pusat dokumen

Projek anda / langkah seterusnya

Keputusan yang baik bermula dengan keperluan yang jelas.

Hantar butiran yang anda ada. Kita boleh memulakan perbualan sementara keperluan yang selebihnya sedang disahkan.

Bincangkan projek anda